Bending beam load cells for approved weighing, automatic systems, dosage.
CAPACITIES (kg): 10, 20, 50, 100, 200, 300, 500.
OIML R60. C3 precision class.
Stainless steel. IP68 protection.
MAIN FEATURES
- C3 PRECISION CLASS
- STAINLESS STEEL
- IP68 PROTECTION
- MAX. CAPACITIES FROM 10 TO 500 kg
- SHIELDED CONNECTION CABLE
- OIML CERTIFICATE AVAILABLE UPON REQUEST
- TEST CERTIFICATE AVAILABLE UPON REQUEST
TECHNICAL FEATURES
- Minimum load cell verification interval: Vmin = EMax / 10.000
- Maximum number of verification intervals: nLC= 3000
- Full Scale Output: 2mV/V ± 1%
- Combined error: 0,017% of Full Scale Output (F.S.)
- Non-Repeatability: 0,015% F.S.
- Temperature effect on zero: ± 0,0014% /°C
- Temperature effect on full scale output: ± 0,0014% /°C
- Compensated Temperature Range: –10°C/+40°C
- Operating Temperature Range: –20°C/+60°C
- Creep error after 30 minutes ± 0,025% F.S.
- Maximum tolerated excitation voltage: 15 VDC
- Input Resistance: 385 ± 20 Ohm
- Output Resistance: 350 ± 5 Ohm
- Insulation Resistance: > 5000 MOhm
- Safe Overload: 150% F.S.
- Ultimate Overload: 200% F.S.
- Nominal displacement: < 0,4 mm
- 4-wire shielded cable, 3m long, 4mm diameter.
ATEX VERSION
- The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
- IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
| Wiring Code |
| Colour |
Function |
| — |
SHIELD |
| BLACK |
OUTPUT + |
| RED |
INPUT + |
| BLUE |
OUTPUT – |
| WHITE |
INPUT – |