METROLOGICAL FEATURES
- Rated capacity: (FS): 30 t, 40 t
- Combined error: 0,022 %F.S
- Creep error (after 30 min.): 0,14 %FS
- Temperature effect on zero: 0,02 %F.S./10°C
- Temperature effect on sensitivity: 0,01 %F.S./10°C
- Non-linearity error: 0,015%F.S.
- Non-repeatability error: 0,006%F.S.
OIML R60
- Vmin= Emax/18000
- Accuracy class: C4
- Max. number of intervals: 4000e (EC Test Certificate, according to OIML R60 (2000))
ELECTRONICMECHANICAL FEATURES
- Gas dischargers to protect against atmospheric discharges
- Double connector for load cells interconnection and weight indicator connection, without junction box.
- Halfduplex RS485 communication technology
- Rice Lake communication protocol
- Power Supply: 8…15 V (AC or DC)
- Rated digital output: 40000 d
- Current consumption: 35 mA
- Internal resolution: 24 bit
- Converter rate: max. 40 conv./sec.
- RS485 communication speed: Max 100kHz.
- Operating temperature: -35 ~ +70 °C
- Compensated temperature: -10 ~ +40 °C
- Storage temperature limits:: -40 ~ 80 °C
- Safe load limit: 150% F.S.
- Ultimate overload: 300% F.S.
- IP68 protection degree
- Stainless steel body
- 4-core RS485 cable as optional with stainless steel shield, diameter 7mm
- Self-centring spherical bases
- Equipped with anti-rotation system, to be combined with 173793 cups for proper operation