Description
TECHNICAL FEATURES
METROLOGICAL:
- Rated capacity (Cn): 30t
- Combined error: ± 0,013 %Cn
- Temperature effect on zero: 0,0014 %Cn/°C
- Temperature effect on sensitivity: 0,0011 %Cn/°C
- Creep error (30 min.): 0,018 %Cn
LEGAL METROLOGY OIML R60
- Accuracy class: C4
- Max. number of intervals (nmax): 4000e OIML
- Minimum verification interval (vmin): 10000
- Z= Emax/(2xDR): 4000
ELECTRICAL
- Nominal range of excitation voltage: 1 – 15Vdc
- Rated output at Cn: 2mV/V
- Zero balance: < ± 2.50%Cn
- Input resistance: 815 ± 20Ω
- Output resistance: 700 ± 0.35Ω
- Current Adjustment: 0,1 %Cn
- Over voltage protection: 10kA/20kV (8/20µs) – IEC61000-4/5
- Insulation resistance: 5000MΩ/50V
GENERAL
- Service temperature range: -20 ~ +60 °C
- Compensated temperature range: -10 ~ +40 °C
- Safe load limit: 150% Emax
- Ultimate overload: 300% Emax
- Protection degree IP68
- Load cells with stainless steel body
- 4-core armoured cable, PVC sheath, 20m length, 7mm diameter.
- Nickel plated steel cable gland.
- Armoured Anti Rodent Cable with Stainless Steel Armour.
- Self-centring spherical bases.
- Equipped with anti-rotation system, to be combined with KRCA cups for proper operation.