Description
TECNICAL FEATURES
METROLOGICAL FEATURES
- Rated capacity: (FS): 30 t, 40 t
- Combined error: 0,02 %F.S
- Creep error (after 30 min.): 0,02 %FS
- Temperature effect on zero: 0,003 %F.S./°C
- Temperature effect on sensitivity: 0,0008 %F.S./°C
OIML R60
- Vmin= Emax/18000
- Accuracy class: C6
- Max. number of intervals: 6000e (EC Test Certificate, according to OIML R60 (2000))
ELECTRONICMECHANICAL FEATURES
- Gas dischargers to protect against atmospheric discharges
- Double connector for load cells interconnection and weight indicator connection, without junction box.
- RS485 communication technology
- Rice Lake communication protocol
- Power Supply: 8…15 Vdc
- Rated digital output: 60000 d
- Current consumption: 35 mA
- Internal resolution: 24 bit
- Converter rate: max. 40 conv./sec.
- RS485 communication speed: Max 100kHz.
- Operating temperature: -20 ~ +70 °C
- Compensated temperature: -10 ~ +40 °C
- Safe load limit: 120% F.S.
- Ultimate overload: 150% F.S.
- IP68 protection degree
- Stainless steel body
- 4-core RS485 cable as optional, 7mm diameter
- Nickel plated steel cable gland
- Self-centring spherical bases
- Equipped with anti-rotation system, to be combined with 173798 cups for proper operation
CONNECTION
| CABLE COLOR CODE | |
|---|---|
| RED | EXCITATION + |
| BLACK | EXCITATION – |
| GREEN | A+ |
| WHITE | B- |
| METAL | Shield |
INSTALLATION KIT
- The 173793 kit allows a correct installation of the RL5426DC load cells below the weighbridge plate.
- The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.