Description
TECNICAL FEATURES
METROLOGICAL FEATURES
- Rated capacity: (F.S.): 20 t, 30 t, 40 t, 50 t
- Combined error: 0,022 %F.S.
- Creep error (after 30 min.): 0,014 %F.S.
- Temperature effect on zero: 0,02 %F.S./10°C
- Temperature effect on sensitivity: 0,01 %F.S./10°C
- Non-linearity error: 0.015%F.S.
- Non-repeatability error: 0.006%F.S.
OIML R60
- Vmin= Emax/14000
- Accuracy class: C4
- Max. number of intervals: 4000e OIML
ELECTRONICMECHANICAL FEATURES
- Gas dischargers to protect against atmospheric discharges
- Power Supply: 5÷15 V (AC or CC)
- Rated output at F.S.: 2 ± 0.05% mV/V
- Input resistance: 800 ± 3Ω
- Output resistance: 700 ± 3Ω
- Insulation resistance: 5000MΩ
- Operating temperature: -35 ~ +70 °C
- Compensated temperature for homologation: -10 ~ +40 °C
- Storage temperature limits: -40° ~ +80°
- Normal service: 120% F.S.
- Maximum load / Safe load: 150% F.S.
- Ultimate overload: 300% F.S.
- IP69K protection degree
- Stainless steel body
- 6-core cable with stainless steel shield, length 20 m, diameter 6mm
- Nickel plated steel cable gland with protective spring
- Self-centring spherical bases
- Equipped with anti-rotation system, to be combined with 173793 cups for proper operation
INSTALLATION KIT
- The 173793 kit allows a correct installation of the RL5416 load cells below the weighbridge plate.
- The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.