Description
MAIN FEATURES
- C3 PRECISION CLASS
- STAINLESS STEEL
- IP68 PROTECTION
- MAX. CAPACITIES FROM 10 TO 500 kg
- SHIELDED CONNECTION CABLE
- OIML CERTIFICATE AVAILABLE UPON REQUEST
- TEST CERTIFICATE AVAILABLE UPON REQUEST
TECHNICAL FEATURES
- Minimum load cell verification interval: Vmin = EMax / 10.000
- Maximum number of verification intervals: nLC= 3000
- Full Scale Output: 2 mV/V ± 0,1%
- Combined error: 0,012% of Full Scale Output (F.S.)
- Non-Repeatability: 0,01% F.S.
- Temperature effect on zero: +/- 0,02% F.S. / 10°C
- Temperature effect on full scale output: +/- 0,02% F.S. / 10°C
- Compensated Temperature Range: –10°C/+50°C
- Operating Temperature Range: –20°C/+60°C
- Creep error after 30 minutes +/- 0,012% F.S.
- Maximum tolerated excitation voltage: 15 VDC
- Input Resistance: 385 ± 10 Ohm
- Output Resistance: 350 ± 3 Ohm
- Insulation Resistance: > 5000 MOhm
- Safe Overload: 120% F.S.
- Ultimate Overload: 150% F.S.
- Nominal displacement: < 0,4 mm
- 4-wire shielded cable, 3m long, 5mm diameter.